Electroplating equipment manufacturer shares: How to troubleshoot equipment pressure abnormalities and solve problems in a timely manner

2026-06-04 08:35:29
times

Sharing of troubleshooting and solutions for abnormal pressure in electroplating equipment

The stable operation of electroplating equipment is the core of coating quality, production efficiency, and safety. However, abnormal fluctuations in pressure parameters (such as drug circulation pressure, compressed air pressure, filtration system pressure difference, etc.) often lead to uneven coating, equipment damage, and even safety accidents. This article combines industry practice experience and shares general troubleshooting ideas and solutions for stress anomalies from four dimensions: anomaly localization, system troubleshooting, process standardization, and preventive maintenance.


1、 Firstly, clarify the types and locations of abnormal pressure

Abnormal pressure is usually divided into two categories: high pressure and low pressure. It is necessary to first locate the abnormal system through the built-in pressure gauge of the equipment (such as the outlet gauge of the circulation pump, the pressure gauge of the gas source, and the differential pressure gauge of the filter):

1. Record abnormal characteristics: amplitude of pressure deviation from normal range (such as exceeding ± 10%), timing of occurrence (sudden/gradual), accompanying phenomena (noise, leakage, vibration, coating defects);

2. Lock the abnormal system: If the outlet pressure of the circulation pump fluctuates, it points to the liquid circulation system; If the pneumatic valve moves slowly, it points to the compressed air system; If the impurities in the filtered medicine increase and the pressure difference increases, it points to the filtration system.


2、 Accurate troubleshooting of pressure anomalies in subsystems

1. Abnormal pressure in the drug circulation system

The liquid circulation system (such as plating solution circulation pumps, pipelines, valves) is a high-risk area for abnormal pressure:

-Excessive pressure:

Common causes: filter blockage (pressure difference>set threshold), pipeline crystallization/impurity blockage, valve not fully open, excessive adjustment of pump outlet valve.

Troubleshooting steps:

-Check the differential pressure gauge of the filter. If the differential pressure exceeds the standard, replace the filter element immediately;

-Close the pipeline valves in sections, observe pressure changes, locate blocked sections, and clean them;

-Check if the valve core is stuck (such as adhesion of electroplating solution crystals), disassemble, clean or replace it;

-Adjust the opening of the pump outlet valve to restore the normal pressure range.

-Low pressure:

Common causes: leakage at the suction end of the pump (seal damage), impeller wear/foreign object jamming, clogged suction filter screen, abnormal viscosity of the liquid medicine (low temperature).

Troubleshooting steps:

-Check the suction end flange and O-ring, replace damaged seals;

-Disassemble the pump body, clean the impeller of foreign objects or replace the worn impeller;

-Clean the suction filter (to prevent impurities from entering the pump body);

-Adjust the temperature of the chemical solution to the process requirements (such as maintaining a nickel plating solution temperature of 50-60 ℃) to reduce viscosity resistance.

2. Abnormal pressure in the compressed air system

The compressed air system (air compressor, pressure reducing valve, pipeline, safety valve) affects the normal operation of pneumatic components (such as valves, agitators):

-Excessive pressure:

Common reasons: Failure of pressure reducing valve (unable to reduce pressure), failure of safety valve to release pressure according to the set pressure.

Troubleshooting steps:

-Test the regulating function of the pressure reducing valve. If the pressure cannot be stabilized, replace it;

-Check if the safety valve opens at the set pressure (such as 0.6-0.8MPa), and if it fails, repair or replace it.

-Low pressure:

Common reasons: insufficient output of air compressor, pipeline leakage, clogged air filter, and overload of air equipment.

Troubleshooting steps:

-Check the pressure display of the air compressor. If the output is low, inspect the tightness of the belt and the wear of the cylinder;

-Apply soapy water to the pipe joints/damaged areas to repair any air leaks;

-Replace the air filter element (when the pressure difference is greater than 0.1MPa);

-Reasonably allocate gas equipment to avoid starting too many pneumatic components simultaneously.

3. Abnormal differential pressure in the filtration system

The core indicator of the filtration system is the inlet and outlet pressure difference:

-Excessive pressure difference: clogged filter element (accumulation of impurities), filter element needs to be replaced immediately (according to the equipment manual cycle or pressure difference threshold);

-Low pressure difference: The filter element is damaged (short circuit of the liquid medicine) or the bypass valve is opened incorrectly. It is necessary to check the integrity of the filter element (observe the cleanliness of the filtrate), close the bypass valve, and repair the blockage.


3、 Investigation process and safety standards

1. Safety prerequisite: Before operation, power must be cut off, valves must be closed, and system pressure must be released (such as opening the vent valve) to avoid the spraying of medication or accidental start-up of equipment;

2. Step by step investigation: from simple to complex (such as checking the valve/filter first, then disassembling the pump body/filter element), to avoid blind disassembly;

3. Verification effect: After solving the problem, start the device and continuously monitor the pressure for more than 30 minutes to confirm stability;

4. Ledger records: Record the cause of abnormalities, solutions, and replacement parts to provide reference for subsequent maintenance.


4、 Daily maintenance to prevent abnormal stress

1. Regular cleaning: Clean the suction filter screen weekly and clean the inner wall of the pipeline monthly (to avoid crystallization);

2. Periodic replacement: Replace the filter element according to regulations (such as PP filter element every 1-2 weeks, precision filter element every 1 month) and seals (every 3-6 months);

3. Calibration equipment: Calibrate pressure gauges and safety valves quarterly to ensure accurate measurement;

4. Process monitoring: Real time monitoring of liquid temperature and concentration to avoid viscosity changes affecting circulation pressure;

5. Personnel training: Familiarize operators with the normal pressure range of the equipment and promptly report any abnormalities.


The investigation of abnormal pressure needs to be combined with system characteristics and practical experience. Through precise positioning and step-by-step solutions, equipment operation can be quickly restored. Daily maintenance is the key to preventing abnormalities, effectively reducing production interruptions and ensuring electroplating quality and safety.